276°
Posted 20 hours ago

Joist Timber Connector Bolt Sets for Joist Repairs (12 Sets) DELIVERY to Mainland UK ONLY

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

Whilst timber floors and their connection details should be designed by a competent person, the ‘Eurocode 5 Span Tables (4th edition)’ published by TRADA offers good advice on typical connection details for solid timbers, such as the sizes of nails or bolts and their location and centres. Some of the key parts of this guidance document in relation to connecting trimmers or trimming joists are summarised below:

So if I have this you're not sistering the joist along it's entire unsupported span, you're attaching a repair section to stiffen it in the damaged area. If you happen to have LVL floor joists, which are uncommon due to their cost, then the process of sistering them would be similar to sistering dimensional lumber. If you are able, find lumber that is the same width as your LVL joist.

Contact

The two 50mm square plate washers play a crucial role in distributing the load evenly across the joist, reducing the risk of localized stress points. They are designed to fit snugly against the timber, providing a stable and balanced support for both the bolt and the joist. The Timber Joist Connector Bolt Set is an essential component for connecting new sections of joist to existing ones that have been compromised by fungal decay. Manufactured to the highest quality standards, this set provides a durable and secure connection, ensuring the structural integrity of timber frameworks. Sandwiching the butt joint of two joists between lengths of similar material will also lengthen a joist to span acceptable distances if longer boards aren’t available or won’t fit. This often requires the use of bolts or lag screws for fastening the sandwiching boards with the joist, especially if the joint is unsupported. Double member trimmers and trimming joists should be fixed in line with a minimum of two nails or two bolts at 1/3 span positions. Furthermore, as a minimum, the fixing centres (S) for double member trimmers and trimming joists should be at centres of no more than twice the joist spacing (up to a maximum of 1200mm). However, required fixing centres vary according to the total length and load on the joists.

If space is limited and you need to fix a sagging or damaged joist, you can partially sister a joist, ensuring you get at least 3’ from the damaged area on either end. The further away from the point of deflection you can get the sistered joist, the better. Sistering a joist with one end at the point of deflection will not result in any significant reduction in the sag.Sistering floor joists is an extremely effective method for fixing a broken floor joist of any kind. Still, it can also be a fairly laborious process as you may have to remove a finished ceiling, wiring, plumbing, HVAC, or other utilities that pass through the problem joist. Why Do You Need to Sister a Floor Joist? Please Note: Every care was taken to ensure the information was correct at the time of publication. Any written guidance provided does not replace the user’s professional judgement. It is the responsibility of the dutyholder or person carrying out the work to ensure compliance with relevant building regulations or applicable technical standards. The nail pattern for double sistering or sandwiching a joist is similar to when sistering a damaged joist, except it should be done from both sides. Alternatively, use two 4” or 4½” lag screws in a ‘W’ pattern, screwing from both sides to bond the tripled section together. Two 5-inch bolts could be used instead of nails or lag screws with two every 12-inches or less, depending on the repair length. Conclusion In other words, these will be 2x2 trimmers on top of the existing beams, as well as new 6x2 running alongside the existing joists and the 2x2 trimmers will also be mitred into these - I am thinking of dropping this latter idea though and just going for the 2x2 trimmers running perpendicularly to the existing joists...

Removing the rim joist will expose the ends of the joist. If they don’t extend beyond the beam, a cantilever extension is possible. Technically, a joist may extend 40% of its supported span past the beam.When sistering a damaged or weak joist with a piece shorter than full length, the ends of the new board are not supported underneath. Double or triple the nail pattern at the ends to improve shear strength. Lag screws or bolts may be used instead of nails, but in a tighter pattern than a doubled joist. For a full sister or doubled joist, three 16d common nails every 16-inches is acceptable. It should be noted that hammering will put additional stress on the piece being sistered. You may choose to predrill and use two 3-inch lag screws or 4-inch bolts every 24-inches instead. Likely, you will only be able to partially sister the joist, as LVLs are used primarily in longer spans that dimensional lumber cannot reach. In that case, follow the same procedure as you would when sistering dimensional lumber. Conclusion The set includes a fully threaded high tensile bolt, M12 nut, two 50mm square plate washers, and one 50mm dog toothed washer. The bolt is precision-engineered with a width of M12 and a length of 150mm, allowing for versatile applications. The fully threaded design ensures a strong and consistent grip, minimizing the risk of loosening over time.

The residential building code does not have a section on sistering joists because it is not standard in new residential construction. Homes are meant to be built on single joists at set spacing – sistering only comes into play if the home has been damaged or improper construction techniques were used, which the building code does not cover. Yip! I had a SE do the calcs and all is well - I can put 18mm T&G chipboard directly on these exist. joists.High-Quality Materials: Each component in this set is crafted from premium materials, guaranteeing durability, longevity, and resistance to corrosion and weathering. As well, I-beams have a flange – the top and bottom – with a narrower web between. This means that in addition to sistering a joist, you have to also include a filler piece to fit between the web and the sistered joist. Prevention of Movement: With its secure bolt and nut system, this connector set prevents unwanted movement or shifting of the joist, ensuring a stable and rigid connection.